79173 - 5040A52 PIPE from condenser to drier filter - R&R
Removing ( Refitting ) See in Op. 5040A10 Air conditioning coolant circuit - Drying and Repressurizing- Open the boot and disconnect the negative battery terminal. See in Op. 1048A28 vacuum air circuit resonator pipe - r+r See in Op. 1048A21 AIR INLET HOSE FROM INTAKE TO FILTER - R.R. See in Op. 1048A11 Air filter assembly - R.R. for versions with automatic transmission 1. Undo the bolt fixing the ipe from the condenser to the drier filter, condenser side.2. Undo the bolt fixing the pipe from the condenser to the drier filter, filter side.3. Remove the pipe from the condenser to the drier filter.
Refitting
(
Removing
)
- Fit the pipe from the condenser to the drier filter, condenser side.- Fit the pipe from the condenser to the drier filter, filter side.
See in Op. 1048A11 Air filter assembly - R.R. for versions with automatic transmission See in Op. 1048A21 AIR INLET HOSE FROM INTAKE TO FILTER - R.R. See in Op. 1048A28 vacuum air circuit resonator pipe - r+r
- Connect the negative battery terminal. See in Op. 5040A10 Air conditioning coolant circuit - Drying and Repressurizing