371573 - N35 THE TELEPHONE DOES NOT WORK

the telephone is integrated in the Connect Node.
STEPOPERATIONS TO BE CARRIED OUTTEST RESULTS
0PRELIMINARY CHECKALL OKPROBLEMS ENCOUNTEREDACTION
Check that the SIM Card is working.Move on to Step SIM Card not workingReplace the SIM Card
1CHECK USING DIAGNOSTIC EQUIPMENTALL OKPROBLEMS ENCOUNTEREDACTION
Connect the Examiner diagnostic equipment to the diagnostic connector and check the following at the Connect Node: In errors ambient

  • that there are no faults
Move on to Step Presence of faultsContinue following the instructions for the diagnostic equipment.
2ELECTRICAL SYSTEM CHECKALL OKPROBLEMS ENCOUNTEREDACTION
Remove the Control Panel, remove the Connect and check that the connector for the telephone aerial is correctly fitted in its housingMove on to Step Connector disconnected from the Connect.Fit the connector in its housing (Wiring Diagram ) E4091 CONNECT
3ELECTRICAL SYSTEM CHECKALL OKPROBLEMS ENCOUNTEREDACTION
Check the continuity/insulation of the connecting cable between the Connect and the G.S.M. aerial (Wiring Diagram ) E4091 CONNECT Move on to Step Aerial lead faultyRestore the electrical connection (Wiring Diagram ) E4091 CONNECT
4CHECK ON CORRECT OPERATIONALL OKPROBLEMS ENCOUNTEREDACTION
Check that the fault is no longer presentFault persistsReplace the aerial mounting.