93552 - 1056B10 AIR FLOW METER - R.R.
Removing ( Refitting ) - Make sure that the ignition key is in the OFF position, then disconnect the negative battery terminal. See in Op. 7040D50 ENGINE COMPARTMENT UPPER SOUND INSULATION SHIELD - R.R. See in Op. 1048A28 vacuum air circuit resonator pipe - r+r See in Op. 1048A21 AIR INLET HOSE FROM INTAKE TO FILTER - R.R. See in Op. 1048A35 HOSE FROM FLOW METER TO RESONATOR - R.R. 1. Disconnect the electrical connection from the air flow meter.2. Undo the nuts (2a) and remove the plates (2b) and the air flow meter (2c).
Refitting
(
Removing
)
- Thoroughly clean the air flow meter and the areas connected with the air filter casing in order to prevent any dirty air from passing through.- Place the air flow meter in its housing and secure it using the plates and the nuts.- Connect the electrical connection to the air flow meter.
See in Op. 1048A35 HOSE FROM FLOW METER TO RESONATOR - R.R. See in Op. 1048A21 AIR INLET HOSE FROM INTAKE TO FILTER - R.R. See in Op. 1048A28 vacuum air circuit resonator pipe - r+r
See in Op. 7040D50 ENGINE COMPARTMENT UPPER SOUND INSULATION SHIELD - R.R.- Connect the negative battery lead.