| 1 | WIRING CONTINUITY CHECK | ALL OK | PROBLEMS ENCOUNTERED | ACTION | 
|---|
|  | Check the continuity of the cable for the speed signal between the body computer and the 14-way connector on the master headlamp (left side)    See E2011  DIPPED HEADLAMPS | Move on to Step 2 | 1. Connector not correctly fitted | 1. Restore the connection | 
| 2. Wiring between body computer and master headlamp faulty | 2. Restore or, if necessary, replace the wiring | 
| 2 | SPEED SIGNAL CHECK | ALL OK | PROBLEMS ENCOUNTERED | ACTION | 
|---|
|  | Check the presence of the speed signal at the 14-way connector for the master headlamp by carrying out the test    See Test 5540BN SPEED SIGNAL CHECK | Move on to Step 3 |  |  | 
| 3 | HEADLAMP INTERNAL WIRING CHECK | ALL OK | PROBLEMS ENCOUNTERED | ACTION | 
|---|
|  | Check the continuity of the wiring between the master and slave headlamp 14-way connector and the control unit side connector by conducting the    See Test 5540BO CHECK THE SPEED SIGNAL WIRING CONTINUITY INSIDE THE MASTER HEADLAMP, then move on to Step 4 | Move on to Step 4 |  |  | 
| 4 | CHECK ON CORRECT OPERATION | ALL OK | PROBLEMS ENCOUNTERED | ACTION | 
|---|
|  | Check the fault has disappeared | End of diagnosis | The fault persists | Refit the headlamp removed previously and replace the master control unitOp. 5540B42 |