939003653 - K062 ABS AND HANDBRAKE WARNING LIGHTS BOTH ON

The handbrake lever is released
The handbrake warning light also indicates a low brake fluid level and, if it is on at the same time as the ABS warning light, a malfunction of the EBD system. The command to switchon the handbrake warning light is sent by the switch on the lever to the Body Computer Node which makes it available on the B-CAN to the Instrument Panel Node.
1PRELIMINARY CHECKSALL OKPROBLEMS ENCOUNTEREDACTION

  • Connect the EXAMINER diagnostic equipment and check the following at the CAN INFORMATION:

  • No faulty control units

  • No control units with faulty CAN
Move on to Step 21. Fault on CAN network1. Continue following the instructions for the diagnostic equipment
2. Impossible to converse with the Body Computer2. Move on to Step 8
2CHECK USING DIAGNOSTIC EQUIPMENTALL OKPROBLEMS ENCOUNTEREDACTION
Keeping the diagnostic equipment connected, check that there are no CAN faults at the BRAKE NODEMove on to Step 2Fault on C-CANMove on to Step 8
3CHECK USING DIAGNOSTIC EQUIPMENTALL OKPROBLEMS ENCOUNTEREDACTION
Using the Examiner check, in the Instrument Panel Node ambient, that there are no errors and that the parameters are present.Move on to Step 4Presence of errorsContinue following the diagnostic equipment information
4ELECTRICAL POWER SUPPLY CHECKALL OKPROBLEMS ENCOUNTEREDACTION
Check that the electrical power supply for the Instrument Panel Node is correctMove on to Step 5Electric power supply positive and/or earth faultyReplace defective component (in the case of a fuse, find out what caused it to blow).
5ELECTRICAL CONNECTIONS CHECKALL OKPROBLEMS ENCOUNTEREDACTION
Check the electrical connections betwen the Body Computer and the Instrument Panel, in particular that each individual pin is correctly connected.Move on to Step 6Electrical connections not working.Renew the damaged electrical connections.
6ACTIVE DIAGNOSIS CHECKALL OKPROBLEMS ENCOUNTEREDACTION
With the Examiner in the Instrument Panel Node ambient check that the warning lights are correctly activated in Active Diagnosis.Move on to Step 7The warning lights are not flashingReplace the Instrument Panel    Op. 5560B10 CONTROL PANEL - R+R
7CHECK USING DIAGNOSTIC EQUIPMENTALL OKPROBLEMS ENCOUNTEREDACTION
Using the Examiner in the Body Computer Node ambient, check that the following errors are not presentMove on to Step 101. Impossible to connect to the Body Computer control unit.1. Move on to Step 8
2. Presence of errors2. Continue following the diagnostic equipment instructions
8ELECTRICAL POWER SUPPLY CHECKALL OKPROBLEMS ENCOUNTEREDACTION
Check that the electrical power supply for the Body Computer Node is correctMove on to Step 9Electric power supply positive and/or earth faultyReplace defective component (in the case of a fuse, find out what caused it to blow).
9CHECK USING DIAGNOSTIC EQUIPMENTALL OKPROBLEMS ENCOUNTEREDACTION
Using the Examiner, check whether it is possible to connect to the Body Computer Node.Move on to Step 10Impossible to connect to the Body Computer control unit.Replace Body Computer    Op. 5505A32 BODY COMPUTER - R.R
10CHECK ON CORRECT OPERATIONALL OKPROBLEMS ENCOUNTEREDACTION
Check that the fault is no longer presentEnd of diagnosis