939003654 - K064 AIR BAG FAILURE WARNING LIGHT ON

The brake fluid warning light remains on with the handbrake released. N.B.: The (negative) brake fluid level signal is sent by the sensor to the Body Computer Node which makes it available via the B-CAN to the Instrument Panel Node. The Instrument Panel Node lights up the dedicated warning light and displays the insufficient brake fluid level message; if the warning light is faulty, the appropriate message is displayed.
0PRELIMINARY CHECKSALL OKPROBLEMS ENCOUNTEREDACTION
Connect the EXAMINER diagnostic equipment and check the following at the CAN INFORMATION:

  • No control units inactive

  • No faulty control units

  • No control units with faulty CAN
Move on to Step 11. Fault on CAN network1. Continue following the instructions for the diagnostic equipment
2. Impossible to converse with the Body Computer2. Move on to Step 2
1CHECK USING DIAGNOSTIC EQUIPMENTALL OKPROBLEMS ENCOUNTEREDACTION
Keeping the Examiner connected, check the plausibility of the brake fluid level parameter at the Body Computer NodeMove on to Step 41.The parameter is not plausible1.Replace body computer    Op. 5505A32 BODY COMPUTER - R.R
2.Impossible to connect to the Body Computer control unit2.Move on to Step 2
2ELECTRICAL POWER SUPPLY CHECKALL OKPROBLEMS ENCOUNTEREDACTION
Check that the electrical power supply for the Body Computer Node is correctMove on to Step 3Electric power supply positive and/or earth faultyReplace defective component (in the case of a fuse, find out what caused it to blow).
3CHECK USING DIAGNOSTIC EQUIPMENTALL OKPROBLEMS ENCOUNTEREDACTION
Using the Examiner, check whether it is possible to connect to the Body Computer Node.Move on to Step 4Impossible to connect to the Body Computer control unitReplace Body Computer    Op. 5505A32 BODY COMPUTER - R.R
4CHECK ON CORRECT OPERATIONALL OKPROBLEMS ENCOUNTEREDACTION
Check that the fault is no longer presentEnd of diagnosisThe fault persistsMove on to Step 5
5BRAKE FLUID LEVEL CHECKALL OKPROBLEMS ENCOUNTEREDACTION
Check that the brake fluid level is not lowMove on to Step 9Insufficient brake fluid levelMove on to Step 6
6BRAKE FLUID LEVEL TOP UPALL OKPROBLEMS ENCOUNTEREDACTION
Top up the brake fluid level and check that the warning light goes outEnd of diagnosisThe warning light does not go outMove on to Step 7
7CHECK USING DIAGNOSTIC EQUIPMENTALL OKPROBLEMS ENCOUNTEREDACTION
Keeping the diagnostic equipment connected, check that there are no CAN faults at the BRAKE NODEMove on to Step 8Fault on C-CANMove on to Step 13
8ELECTRICAL SYSTEM CHECKALL OKPROBLEMS ENCOUNTEREDACTION
Disconnect the connector from the oil level sensor and check that it is working properly    See E4010 INSTRUMENT PANEL     See table X01 EXCESSIVE FUEL CONSUMPTION Move on to Step 9Brake fluid level sensor defectiveReplace the sensorOp. 3330A30 DEVICE SIGNALLING BRAKE FLUID LEVEL - CHECK DEVICE ON TANK - INCLUDES REPLACING CAP AND TOPPING UP LEVEL, IF NECESSARY
9ELECTRICAL SYSTEM CHECKALL OKPROBLEMS ENCOUNTEREDACTION
Check the continuity of the cable from the connector to the Body Computer    See E4010 INSTRUMENT PANEL Move on to Step 10Lead brokenRestore the correct connection.
10CHECK USING DIAGNOSTIC EQUIPMENTALL OKPROBLEMS ENCOUNTEREDACTION
Connect the Examiner and check that plausibility of the handbrake applied parameter at the Body Computer NodeMove on to Step 11The parameter is not plausibleProceed as instructed by the    See table K072 HANDBRAKE APPLIED WARNING LIGHT
11CHECK USING DIAGNOSTIC EQUIPMENTALL OKPROBLEMS ENCOUNTEREDACTION
Connect the Examiner or keep it connected and check the operation of the brake fluid level warning light in active diagnosis at the Instrument Panel NodeMove on to Step 12The warning light does not flashReplace instrument panel    Op. 5560B10 CONTROL PANEL - R+R
12ELECTRICAL POWER SUPPLY CHECKALL OKPROBLEMS ENCOUNTEREDACTION
Check that the electrical power supply for the Instrument Panel Node is correctMove on to Step 13Electric power supply positive and/or earth faultyReplace the defective component (in the case of a fuse, find out what caused it to blow). 13
13ELECTRICAL CONNECTIONS CHECKALL OKPROBLEMS ENCOUNTEREDACTION
Check the electrical connections betwen the Body Computer and the Instrument Panel, in particular that each individual pin is correctly connected.Move on to Step 14Electrical connections not working.Renew the damaged electrical connections.
14CHECK USING DIAGNOSTIC EQUIPMENTALL OKPROBLEMS ENCOUNTEREDACTION
Keeping the Examiner connected, check the plausibility of the brake fluid level parameter at the Body Computer NodeMove on to Step 15The parameter is not plausibleReplace body computer    Op. 5505A32 BODY COMPUTER - R.R
15CHECK ON CORRECT OPERATIONALL OKPROBLEMS ENCOUNTEREDACTION
Check that the fault is no longer presentEnd of diagnosis