939003657 - K072 HANDBRAKE APPLIED WARNING LIGHT

The warning light is on constantly even with the handbrake released.
N.B.: The command to switch on the handbrake warning light is sent by the switch on the lever to the Body Computer Node which makes it available on the B-CAN to the Instrument Panel Node.
0PRELIMINARY CHECKSALL OKPROBLEMS ENCOUNTEREDACTION
Check that the ABS warning light comes on and goes out during the initial testMove on to Step 1The ABS warning light also remains onContinue as instructed in the    See table K062 ABS AND HANDBRAKE WARNING LIGHTS BOTH ON
1ELECTRICAL SYSTEM CHECKALL OKPROBLEMS ENCOUNTEREDACTION
Check the insulation to earth of the wiring between the Handbrake lever switch and the Body ComputerMove on to Step 2Wiring not insulatedRestore wiring    See E4010 INSTRUMENT PANEL
2SWITCH CHECKALL OKPROBLEMS ENCOUNTEREDACTION
Check the condition of the switch on the handbrake leverMove on to Step 3Switch defectiveReplace the switch    Op. 5550D18 HANDBRAKE ON WARNING LIGHT SWITCH - R+R
3ACTIVE DIAGNOSIS CHECKALL OKPROBLEMS ENCOUNTEREDACTION
With the Examiner in the Instrument Panel Node ambient check that the handbrake warning light is correctly activated in Active Diagnosis.Move on to Step 61. The handbrake warning light does not flash1.Replace the Instrument Panel    Op. 5560B10 CONTROL PANEL - R+R
2. Impossible to connect with the Instrument Panel Node2.Move on to Step 4
4CHECK USING DIAGNOSTIC EQUIPMENTALL OKPROBLEMS ENCOUNTEREDACTION
Using the Examiner check, in the Instrument Panel Node ambient, that there are no errors and that the parameters are presentMove on to Step 5Presence of errorsContinue following the diagnostic equipment information
5ELECTRICAL POWER SUPPLY CHECKALL OKPROBLEMS ENCOUNTEREDACTION
Check that the electrical power supply for the Instrument Panel Node is correctMove on to Step 6Electric power supply positive and/or earth faultyReplace defective component (in the case of a fuse, find out what caused it to blow).
6ELECTRICAL CONNECTIONS CHECKALL OKPROBLEMS ENCOUNTEREDACTION
Check the electrical connections betwen the Body Computer and the Instrument Panel, in particular that each individual pin is correctly connectedMove on to Step 7Electrical connections not workingRenew the damaged electrical connections
7CHECK USING DIAGNOSTIC EQUIPMENTALL OKPROBLEMS ENCOUNTEREDACTION
Using the Examiner check, in the Body Computer ambient, that there are no errors and that the parameter specified variesMove on to Step 101. Impossible to connect to the Body Computer control unit1. Move on to Step 8
2. Presence of errors2. Continue following the diagnostic equipment instructions
3. The parameter values do not change3. Move on to Step 9
8ELECTRICAL POWER SUPPLY CHECKALL OKPROBLEMS ENCOUNTEREDACTION
Check that the electrical power supply for the Body Computer Node is correctMove on to Step 9Electric power supply positive and/or earth faultyReplace defective component (in the case of a fuse, find out what caused it to blow).
9CHECK USING DIAGNOSTIC EQUIPMENTALL OKPROBLEMS ENCOUNTEREDACTION
Using the Examiner, check whether it is possible to connect to the Body Computer NodeMove on to Step 10Impossible to connect to the Body Computer control unitReplace Body Computer    Op. 5505A32 BODY COMPUTER - R.R
10CHECK ON CORRECT OPERATIONALL OKPROBLEMS ENCOUNTEREDACTION
Check that the fault is no longer presentEnd of diagnosis