939003665 - K095 INSTRUMENT PANEL NOT WORKING

With the ignition ON, some of the warning lights are not timed and the instruments are not working with the engine running.
0PRELIMINARY CHECKSALL OKPROBLEMS ENCOUNTEREDACTION
Connect an EXAMINER and check the following on CAN NETWORK INFORMATION:

  • No control units inactive
  • No faulty control units
  • no control units with faulty CAN
Move on to Step 11. Fault on CAN network1. Continue following the instructions for the diagnostic equipment
2. Communication impossible with the Body Computer2. Move on to Step 2
1CHECK USING DIAGNOSTIC EQUIPMENTALL OKPROBLEMS ENCOUNTEREDACTION
Using an Examiner check, in Instrument Panel mode, that there are no errors and that the parameters are presentMove on to Step 41. Presence of errors1. Continue following the instructions on the diagnostic instrument
2. Communication impossible with the instrument panel2. Move on to Step 3
2ELECTRICAL POWER SUPPLY CHECKALL OKPROBLEMS ENCOUNTEREDACTION
Check the electricity supply to the Instrument Panel Node is correct by carrying out the testSee Test 5560BV INSTRUMENT PANEL POWER SUPPLY CHECKMove on to Step 3Fault in positive electrical supply and/or earthReplace defective component (in the case of a fuse, find out what caused it to blow)
3CHECK ELECTRICAL CONNECTIONSALL OKPROBLEMS ENCOUNTEREDACTION
Check the wiring between the Body Computer and the Instrument Panel. In particular, check that each individual pin is properly connectedMove on to Step 4Electrical connections not operationalRenew the damaged electrical connections
4CHECK USING DIAGNOSTIC EQUIPMENTALL OKPROBLEMS ENCOUNTEREDACTION
Using an Examiner check, in Body Computer Node mode, that there are no errorsMove on to Step 71. Impossible to connect to the Body Computer control unit.1. Move on to Step 5
2. Presence of errors2. Continue by following the instructions on the diagnostic instrument
5ELECTRICAL POWER SUPPLY CHECKALL OKPROBLEMS ENCOUNTEREDACTION
Check the electricity supply to the Body Computer Node is correct.Move on to Step 6Fault in positive electrical supply and/or earthReplace defective component (in the case of a fuse, find out what caused it to blow).
6CHECK USING DIAGNOSTIC EQUIPMENTALL OKPROBLEMS ENCOUNTEREDACTION
Use an Examiner to check the possibility of connection to the Body Computer Node.Move on to Step 7Impossible to connect to the Body Computer control unit.Replace Body Computer    Op. 5505A32 BODY COMPUTER - R.R
7CHECK ON CORRECT OPERATIONALL OKPROBLEMS ENCOUNTEREDACTION
Check that the fault is no longer presentEnd of diagnosisThe fault persistsReplace the Instrument Panel    Op. 5560B10 CONTROL PANEL - R+R