939003692 - K166 RAIN SENSOR WARNING LIGHT ON CONSTANTLY

1CHECK USING DIAGNOSTIC EQUIPMENTALL OKPROBLEMS ENCOUNTEREDACTION
Using the Examiner check, in the Instrument Panel Node ambient, that there are no errors.Move on to Step 2Errors presentContinue as described by the diagnostic equipment
2ACTIVE DIAGNOSIS CHECKALL OKPROBLEMS ENCOUNTEREDACTION
With the Examiner in the Instrument Panel Node ambient check that the rain sensor failure warning light is correctly activated in Active DiagnosisMove on to Step 3The warning light does not flashReplace the Instrument Panel    Op. 5560B10 CONTROL PANEL - R+R
3CHECK USING DIAGNOSTIC EQUIPMENTALL OKPROBLEMS ENCOUNTEREDACTION
Using the Examiner check, in the Body Computer ambient, that there are no errors.Move on to Step 4Errors presentContinue as described by the diagnostic equipment
4CHECK USING DIAGNOSTIC EQUIPMENTALL OKPROBLEMS ENCOUNTEREDACTION
Using the Examiner in the Body Computer ambient in Active Diagnosis that the serial line between the rain sensor and the Body Computer is in good condition    See E2010 SIDE LIGHTS / NO. PLATE LIGHTS Move on to Step 51.Serial line broken1.Renew serial line continuity    See E2010 SIDE LIGHTS / NO. PLATE LIGHTS
2.Serial line short circuited2.Renew serial line insulation
5CORRECT POWER SUPPLY CHECKALL OKPROBLEMS ENCOUNTEREDACTION
Check that the power supply for the rain sensor is correct    See E2010 SIDE LIGHTS / NO. PLATE LIGHTS Move on to Step 61.Sensor not correctly connected to earth1.Restore earth connection    See E2010 SIDE LIGHTS / NO. PLATE LIGHTS
2.Power supply interrupted2.Restore correct power supply    See E2010 SIDE LIGHTS / NO. PLATE LIGHTS
6RAIN SENSOR CHECKALL OKPROBLEMS ENCOUNTEREDACTION
Check that the rain sensor is working properly.End of diagnosisRain sensor not working properly.Replace the rain sensor    Op. 5050B70 RAIN/DUSK SENSOR - R.R.