939005375 - A005 ALARM LED NOT WORKING

When the alarm is activated, the control LED does not switch off
Test results
1CHECK USING DIAGNOSTIC EQUIPMENTAll OKProblems encounteredOperation
Connect the diagnostic equipment (Examiner Plus or Smart) and check that there are no faults in the systemEnd of diagnosisThere are faults presentMove on to Step 2
2ACTIVE DIAGNOSIS WITH DIAGNOSTIC EQUIPMENTAll OKProblems encounteredOperation
Using the diagnostic equipment carryout the active diagnosis of the LED activationEnd of diagnosisThe LED is not activatedMove on to Step 3
3CHECK THE WIRINGAll OKProblems encounteredOperation
Check the continuity and insulation of the wiring between the Body Computer and the door panelCheck that the supply for the LED leaves the Body Computer and that the LED comes on    See E7015 ALARMEnd of diagnosisThe supply for the LED does not leave the Body ComputerReplace Body Computer    Op. 5505A32 BODY COMPUTER - R.R
The supply is sent from the Body Computer but the LED does not light upReplace the LED.