939010563 - 1060G10 AIR FLOW METER - R.R.

Removing ( Refitting )
If the air flow meter is being replaced, when the refitting is complete the following operations must be carried out using the Examiner.
- Make sure that the ignition key is in the OFF position, then disconnect the battery terminal (-).    Op. 1048A41 HOSE FROM FLOW METER TO TURBOCHARGER - R.R.1. Disconnect the electrical connection from the air flow meter.
DescriptionConnector
1Air flow meter    See K041 AIR FLOW METER
2. Loosen the band (2a) and remove the air flow meter (2b).
Refitting ( Removing ) - Place the air flow meter back in its housing and secure it using the band.- Connect the electrical connection to the air flow meter.    Op. 1048A41 HOSE FROM FLOW METER TO TURBOCHARGER - R.R.- Connect the negative battery terminal.