| 0 | PRELIMINARY CHECKS | ALL OK | PROBLEMS ENCOUNTERED | ACTION | 
|---|
|  | Check that the ABS warning light comes on and goes out during the initial test | Move on to Step 1 | The ABS warning light also remains on | Continue as instructed in the    See table K062 ABS AND HANDBRAKE WARNING LIGHTS BOTH ON | 
| 1 | ELECTRICAL SYSTEM CHECK | ALL OK | PROBLEMS ENCOUNTERED | ACTION | 
|---|
|  | Check the insulation to earth of the wiring between the Handbrake lever switch and the Body Computer | Move on to Step 2 | Wiring not insulated | Restore wiring    See E4010  INSTRUMENT PANEL | 
| 2 | SWITCH CHECK | ALL OK | PROBLEMS ENCOUNTERED | ACTION | 
|---|
|  | Check the condition of the switch on the handbrake lever | Move on to Step 3 | Switch defective | Replace the switch    Op. 5550D18 HANDBRAKE ON WARNING LIGHT SWITCH - R+R | 
| 3 | ACTIVE DIAGNOSIS CHECK | ALL OK | PROBLEMS ENCOUNTERED | ACTION | 
|---|
|  | With the Examiner in the Instrument Panel Node ambient check that the handbrake warning light is correctly activated in Active Diagnosis. | Move on to Step 6 | 1. The handbrake warning light does not flash | 1.Replace the Instrument Panel    Op. 5560B10  CONTROL PANEL - R+R | 
| 2. Impossible to connect with the Instrument Panel Node | 2.Move on to Step 4 | 
| 4 | CHECK USING DIAGNOSTIC EQUIPMENT | ALL OK | PROBLEMS ENCOUNTERED | ACTION | 
|---|
|  | Using the Examiner check, in the Instrument Panel Node ambient, that there are no errors and that the parameters are present | Move on to Step 5 | Presence of errors | Continue following the diagnostic equipment information | 
| 5 | ELECTRICAL POWER SUPPLY CHECK | ALL OK | PROBLEMS ENCOUNTERED | ACTION | 
|---|
|  | Check that the electrical power supply for the Instrument Panel Node is correct | Move on to Step 6 | Electric power supply positive and/or earth faulty | Replace defective component (in the case of a fuse, find out what caused it to blow). | 
| 6 | ELECTRICAL CONNECTIONS CHECK | ALL OK | PROBLEMS ENCOUNTERED | ACTION | 
|---|
|  | Check the electrical connections betwen the Body Computer and the Instrument Panel, in particular that each individual pin is correctly connected | Move on to Step 7 | Electrical connections not working | Renew the damaged electrical connections | 
| 7 | CHECK USING DIAGNOSTIC EQUIPMENT | ALL OK | PROBLEMS ENCOUNTERED | ACTION | 
|---|
|  | Using the Examiner check, in the Body Computer ambient, that there are no errors and that the parameter specified varies | Move on to Step 10 | 1. Impossible to connect to the Body Computer control unit | 1. Move on to Step 8 | 
| 2. Presence of errors | 2. Continue following the diagnostic equipment instructions | 
| 3. The parameter values do not change | 3. Move on to Step 9 | 
| 8 | ELECTRICAL POWER SUPPLY CHECK | ALL OK | PROBLEMS ENCOUNTERED | ACTION | 
|---|
|  | Check that the electrical power supply for the Body Computer Node is correct | Move on to Step 9 | Electric power supply positive and/or earth faulty | Replace defective component (in the case of a fuse, find out what caused it to blow). | 
| 9 | CHECK USING DIAGNOSTIC EQUIPMENT | ALL OK | PROBLEMS ENCOUNTERED | ACTION | 
|---|
|  | Using the Examiner, check whether it is possible to connect to the Body Computer Node | Move on to Step 10 | Impossible to connect to the Body Computer control unit | Replace Body Computer    Op. 5505A32  BODY COMPUTER - R.R | 
| 10 | CHECK ON CORRECT OPERATION | ALL OK | PROBLEMS ENCOUNTERED | ACTION | 
|---|
|  | Check that the fault is no longer present | End of diagnosis |  |  |