939005365 - 5510CC IGNITION COIL CHECK

CHECK TO BE PERFORMEDRESOLUTION IF THE CHECK IS NOT OK
1Connect the diagnostic equipment and check that none of the following errors is present: P0300, P0301, P0302, P0303, P0304Continue as described by the diagnostic equipment
2Start the engine and let it warm up.Keep the engine at a speed of 2000 rpm and check that there is no misfire.The test may be considered over. Move on to Step 3
3Press the START/STOP button (engine off).Disconnect the corresponding cylinder coil.Press the START/STOP button (panel on).Measure the voltage between Pin 2 of the coil    See A030 IGNITION COIL and the Earth, checking that it corresponds to the battery voltageMove on to Step 7
4Measure the voltage between Pins 2 and 3 of the coil    See A030 IGNITION COIL checking that it corresponds to the battery voltageRestore or, if necessary, replace the electrical wiring    See E5030 PETROL ENGINES ELECTRONIC MANAGEMENT Move on to Step 9
5Measure the voltage between Pins 2 and 4 of the coil    See A030 IGNITION COIL checking that it corresponds to the battery voltageRestore or, if necessary, replace the electrical wiring    See E5030 PETROL ENGINES ELECTRONIC MANAGEMENT Move on to Step 9
6If faults are present, repair or if necessary replace the ignition coil electrical wiring.    See E5030 PETROL ENGINES ELECTRONIC MANAGEMENT Move on to Step 9Replace the faulty ignition coilOp. 5510C05 ELECTRONIC POWER MODULE - R RMove on to Step 9
7Check that none of the components connected to the same line as the coil has faults in the electrical connections such as short circuits or poor insulation    See E5030 PETROL ENGINES ELECTRONIC MANAGEMENT Restore or, if necessary, replace the electrical wiring    See E5030 PETROL ENGINES ELECTRONIC MANAGEMENT Move on to Step 9
8Replace the coil protective fuse    See E5030 PETROL ENGINES ELECTRONIC MANAGEMENT
9Reconnect all the electrical components disconnected previously.Using the diagnostic equipment delete the errors in the engine management control unit.Start the engine and check that there are no longer any errorsContinue as described by the diagnostic equipment