939010680 - 1088D10 LOWER RADIATOR COOLANT OUTLET HOSE - R.R.

Removing ( Refitting )     Op. 0010T20 ENGINE COOLANT - CHANGE 1. Loosen the band (1a) and disconnect the water return pipe (1b) from the water-oil heat exchanger from the water pump inlet hose (1c)2. Loosen the band and disconnect the hose (1c) from the water pump rigid inlet pipe.3. Disconnect the rapid connector and remove the radiator water outlet hose assembly (1c).
- If necessary, loosen the fastening bands and remove the three-way connector and the connector with the rapid connector. Refitting ( Removing ) - Place the connector with the rapid connector and the three-way connector in position and secure them using the bands.- Place the radiator water outlet hose assembly in position and connect the rapid connector.- Connect the hose to the water pump rigid inlet pipe using the band.- Connect the water return pipe from the water-engine oil heat exchanger to the water pump inlet hose using the band.    Op. 0010T20 ENGINE COOLANT - CHANGE