939005418 - W20 POLLUTANT EMISSIONS IN VEHICLE
|  | Pollutant emissions enter the vehicle during automatic operation (failed automatic operation of the recirculation flaps) | 
| 1 | RECIRCULATION MOTOR ELECTRICAL CIRCUIT CHECK | All OK | Problems encountered | Operation | 
|---|---|---|---|---|
| Check the operation of:- air recirculation motor;- connection between air motor and climate control system control unit: See E6020 AIR CONDITIONING - control on climate control system control unit. | Move on to Step 2 | Recirculation motor defective | Replace the recirculation motor Op. 5040D75 AIR CONDITIONING RECIRCULATION FLAP CONTROL MOTOR - R.R | |
| Connections between recirculation motor and control unit not correct. | Restore the correct connection See E6020 AIR CONDITIONING | |||
| Control on control unit defective. | Replace the climate control system control unit Op. 5040D18 AIR CONDITIONING CONTROL UNIT - R.R. | |||
| 2 | POLLUTION SENSOR CHECK | All OK | Problems encountered | Operation | 
| Check that the pollution sensor is correctly supplied and working properly by carrying out the See Test 5040DD Check operation of pollution sensor (AQS) | End of diagnosis | AQS sensor not correctly supplied | Restore the correct power supply See E6020 AIR CONDITIONING | |
| AQS sensor not working properly. | Replace the AQS sensor Op. 5010D72 AIR QUALITY SENSOR - R.R. FOLLOWING ELECTRICAL CIRCUIT CHECK |