939010563 - 1060G10 AIR FLOW METER - R.R.

Removing ( Refitting )
If the air flow meter is replaced, reset using an examiner after refitting.
- Make sure that the ignition key is in the OFF position, then disconnect the battery terminal (-).
DescriptionConnector
-Battery    See A001 BATTERY
    Op. 1016A10 SOUND-PROOFING COVER - R.R 1. Disconnect the electrical connection from the air flow meter.
DescriptionConnector
1Air flow meter    See K041 AIR FLOW METER
2. Loosen collars (2a) and disconnect air sleeve (2b) from the air flow meter and resonator.3. Loosen the band (3a) and remove the air flow meter (3b).
Refitting ( Removing ) - Place the air flow meter back in its housing and secure it using the band.- Connect the air sleeve to the air flow meter and resonator and tighten the bands.- Connect the electrical connection to the air flow meter.    Op. 1016A10 SOUND-PROOFING COVER - R.R - Connect the negative battery terminal.