194002936 - Y096 P2620 - MOTORISED THROTTLE (FEEDBACK)

The diagnostic equipment signals: Error P2620 (motorized throttle (feedback).
This error is detected if the control unit recognizes a malfunction in the circuit through an internal logic evaluation: short circuit to earth/positive or break in the connecting circuit at Pin 59 of the junction unit.
1Check on throttle casing operationALL OKPROBLEMS ENCOUNTEREDACTION
Check that the integrated throttle casing actuator is working properly by carrying out the test    See Test 1060GO CHECK ON OPERATION OF MOTORIZED THROTTLE CASINGEnd of diagnosis