198001677 - A032 ALARM DOES NOT GO OFF WITH BOOT RELEASE

When the opening of the boot is requested using the remote control, the alarm system does not switch off.
In operational mode, the system, on receiving the boot lid opening command, disables the volumetric external modules and the perimeter protection from the boot switch inlet.
TEST RESULTS
1CHECK USING DIAGNOSTIC EQUIPMENTALL OKPROBLEMS ENCOUNTEREDACTION
Connect the diagnostic equipment to the body computer node and check, in parameters mode, that the boot lid status (open or closed) is correctly received.Check the remote control button is working properlyMove on to Step 31. The status of the boot lid is not received.2. Remote control defective.1. Move on to Step 22. Replace the remote control
2ELECTRICAL CIRCUIT CHECKALL OKPROBLEMS ENCOUNTEREDACTION
Check that the electrical connection between the boot lid switch and the door control unit is not broken.Move on to Step 3Electrical connection interruptedRestore the continuity of the electrical connection between the boot lid switch and the body computer node    See E7015 ALARM
3COMPONENT OPERATION CHECKALL OKPROBLEMS ENCOUNTEREDACTION
Disconnect the connector, body computer node side, and check for the presence of the boot lid open/closed signal    See E7015 ALARMMove on to Step 4Boot lid electric switch not working.Replace the boot lid lock    Op. 7015B10 SINGLE TAILGATE LOCK - R+R OR REPAIR WITH PANEL/PROTECTION REMOVED
4CORRECT OPERATION CHECKALL OKPROBLEMS ENCOUNTEREDACTION
Check that the fault is no longer presentEnd of diagnosisThe fault persistsReplace body computer    Op. 5505A35 MAIN BODY COMPUTER/JUNCTION UNIT - R.R.