198001679 - A035 TILT SENSOR ALARM NOT WORKING

When the alarm is switched on using the remote control, the system is activated correctly but the anti-tilt sensor does not interveneThe sensor is connected to the body computer node through an A-Bus serial line.
TEST RESULTS
1CHECK USING DIAGNOSTIC EQUIPMENTALL OKPROBLEMS ENCOUNTEREDACTION
Connect the Examiner diagnostic equipment to the diagnostic socket and check the following at the body computer node in parameters mode:- the presence of the tilt sensorIn errors mode:that there are no problems relating to the anti-tilt sensorMove on to Step 2Presence of faultsProceed as instructed by the diagnostic equipment
2ULTRASOUND SENSORS CHECKALL OKPROBLEMS ENCOUNTEREDACTION
Check the anti-tilt sensor is correctly connected via the A-Bus serial line to the body computer    See E7015 ALARMMove on to Step 3Connections not correctRestore the correct connections.
3CHECK USING DIAGNOSTIC EQUIPMENTALL OKPROBLEMS ENCOUNTEREDACTION
Connect the Examiner diagnostic equipment to the diagnostic socket and check the following at the body computer node. In active diagnosis:the operation of the volumetric modulesEnd of diagnosis1. Anti-tilt sensor defective2. Body computer defective1. Replace the anti-tilt and ultrasound sensors module.2. Replace body computer    Op. 5505A35 MAIN BODY COMPUTER/JUNCTION UNIT - R.R.