198001675 - A030 ALARM NOT WORKING LUGGAGE COMPARTMENT UNLOCKED

With the alarm on, the boot lid unlocking command is not enabled by the remote control.
The boot lid locking/unlocking command is controlled by the body computer node, which sends a signal to the electric lock through the door management control unit and receives and memorizes the causes of malfunction.
TEST RESULTS
0PRELIMINARY CHECKALL OKPROBLEMS ENCOUNTEREDACTION
Make sure that the central locking system is working properly. In particular, check that the "independent boot" option is disabled.Then close the doors using the mechanical key.Move on to Step 11. Central locking not working: the doors and the boot lid are not closed/opened simultaneously.2. Central locking not working: the doors and the boot lid are not closed/opened simultaneously.1. Proceed with the diagnosis of the central locking system    See table P010 CENTRAL LOCKING NOT WORKING2. Move on to Step 3
1CHECK USING DIAGNOSTIC EQUIPMENTALL OKPROBLEMS ENCOUNTEREDACTION
Connect the diagnostic equipment to the body computer node and check that there are no errors.Move on to Step 2Presence of errorsContinue as instructed by the diagnostic equipment.
2CHECK USING DIAGNOSTIC EQUIPMENTALL OKPROBLEMS ENCOUNTEREDACTION
Keeping the Examiner diagnostic equipment connected, check, in the parameters mode, that the boot lid opening/closing command using the remote control is correctly received.Move on to Step 31. The boot lid opening/closing command using the remote control is not received.2. The boot lid opening/closing command using the remote control is received.1. Move on to Step 32. Replace lock
3CHECK USING DIAGNOSTIC EQUIPMENTALL OKPROBLEMS ENCOUNTEREDACTION
In parameters mode, check that the remote control(s) is(are) working properly, in particular that the reception is OK for each individual button.Move on to Step 4The individual remote control commands are not received correctlyReplace the broken remote control(s).
4ELECTRICAL CIRCUIT CHECKALL OKPROBLEMS ENCOUNTEREDACTION
Check the continuity/insulation of the electrical connection between the boot lid lock and the door management control unitMove on to Step 5Electrical connection interrupted or not insulated.Restore the damaged electrical connection    See E7015 ALARM
5CORRECT OPERATION CHECKALL OKPROBLEMS ENCOUNTEREDACTION
Check that the fault is no longer presentEnd of diagnosis1. Replace door management control unit2. Replace body computer1. Replace door management control unit    Op. 7005N40 CENTRAL LOCKING ELECTRICAL CONTROL UNIT - R R FOLOWING SYSTEM CHECK2. Replace the body computer node    Op. 5505A35 MAIN BODY COMPUTER/JUNCTION UNIT - R.R.